DKross™ PTCA Balloon Dilatation Catheter

Product Description

Broad size matrix 1.25-4.0mm diameters & 10-40mm lengths Smallest NC Balloon (1.25/1.5/1.75 mm) with the highest RBP at 20 atm Flexible, soft tip for challenging anatomy Recommended choice for pre-dilatation & post-dilatation

Products Information

The DKross™ PTCA Balloon Dilatation Catheter is a rapid-exchange (Rx) non-compliant coronary balloon catheter developed for percutaneous transluminal coronary angioplasty (PTCA). It is intended for lesion pre-dilatation and post-dilatation during PCI procedures, offering controlled balloon expansion, high-pressure capability, and improved deliverability in complex coronary anatomy.

Key Features

  • Non-compliant (NC) balloon technology for precise vessel expansion with minimal balloon growth at high pressure
  • Rated Burst Pressure (RBP): 20 atm for aggressive lesion preparation and stent optimization
  • Low-profile flexible tip designed to improve crossability in tortuous or calcified lesions
  • Rapid Exchange (Rx) design compatible with standard interventional workflow
  • 5F guiding catheter compatibility supports minimally invasive access strategies
  • Broad matrix of balloon sizes for different coronary anatomies and lesion types

Technical Specifications

SpecificationDetails
Catheter TypeRapid Exchange (Rx)
Guidewire Compatibility0.014″
Compliance TypeNon-compliant
Balloon Diameters1.25 mm – 4.00 mm
Balloon Lengths10 mm – 40 mm
Catheter Length142 cm
Guiding Catheter Compatibility5F
Nominal Pressure10 atm
Rated Burst Pressure20 atm
Balloon MaterialNylon

Available Balloon Sizes

Diameter Range

  • 1.25 mm
  • 1.50 mm
  • 1.75 mm
  • 2.00 mm
  • 2.25 mm
  • 2.50 mm
  • 2.75 mm
  • 3.00 mm
  • 3.50 mm
  • 4.00 mm

Length Range

  • 10 mm
  • 15 mm
  • 20 mm
  • 25 mm
  • 30 mm
  • 35 mm
  • 40 mm

Clinical Advantages

The DKross™ NC balloon platform is designed to support:

  • Enhanced stent expansion accuracy
  • Reduced uncontrolled balloon growth
  • Improved lesion preparation before stent implantation
  • Effective post-dilatation at high pressures
  • Better scaffolding performance in resistant lesions

According to the manufacturer documentation, non-compliant balloons may improve dilatation outcomes and reduce dissection rates compared with semi-compliant balloons in certain PCI applications.

Typical Applications

  • Coronary artery stenosis treatment
  • Pre-dilatation before DES/BMS implantation
  • Post-dilatation for stent optimization
  • Resistant or fibrotic coronary lesions
  • Complex PCI procedures requiring high-pressure expansion

Manufacturer

Manufactured by DK Medical Technology Co., Ltd.

Product page:
DKross™ PTCA Balloon Dilatation Catheter

Technical brochure:
DKross™ Product PDF